Sign In | Join Free | My howtoaddlikebutton.com
China Ningbo Sanxing Electric Co., Ltd. logo
Ningbo Sanxing Electric Co., Ltd.
Active Member

10 Years

Home > Other meter >

Intelligent On The Spot Terminal

Ningbo Sanxing Electric Co., Ltd.

Intelligent On The Spot Terminal

Packaging Details : Carton

Place of Origin : Zhejiang,

Production Capacity : 15, 000, 000 pcs/year

Model Number : SX129ZN-GK2

Brand Name : Sanxing

Standard : IEC, ANSI

Main Markets : North America, South America, Southeast Asia, Africa, Mid East, Eastern Asia

HS Code : 9028301900

Category : Energy Meters

Contact Now

Conformed Standards
@IEC 62053-21: 2003: Alternating Current Static Watt-hour Meters for Active Energy (classes 1 and 2)
@DL/T 743-2001: Remote terminal unit of integrated totals
@DL/T 721-2000: Remote Terminal Function of Distributing Net Automation System
@DL/T 533-93: Radio load control two-way terminal technical requirement
Main Features
@Advanced measuring chip with high reliable CPU and manufactured with advanced SMT process
@Forward/Reverse active/reactive energy measurement, total active/reactive energy measurement, 4-quadrant reactive energy measurement
@Active energy measurement of each phase, active/reactive energy measurement of each tariff, total energy measurement, MD measurement, the time of power on or off
@Instantaneous parameter measurement: RMS voltage, RMS current, power factor, frequency, power
@State measurement: The time of phase failure, current missing and potential missing
@Meter reading by GPRS/CDMA, programmable time interval and content, such as phase current, phase voltage, potential missing, current missing, phase failure, reactive power, active power, current MD, MD last month, RTC, etc.
@Data reserve: Load profile, daily data, monthly data, alarm event, instantaneous parameter measurement
@Daily data: Daily active energy of each tariff, daily total active energy, daily reactive energy of each tariff, daily total reactive energy, default daily data reading at 0 oclock or other time which is programmable, the accumulated time of exceeding upper limit and lower limit, which are programmable.
@Monthly data: Monthly active energy of each tariff, monthly total active energy, monthly reactive energy of each tariff, monthly total reactive energy, default monthly data reading at 0 oclock of the end of month or other time which is programmable, the accumulated time of exceeding upper limit and lower limit, which are programmable, and voltage qualification rate, MD and the time of MD happening.
@Profile data: Monthly active energy, monthly reactive energy, 4-quadrant reactive energy, phase current, phase voltage, phase power, total power, reactive power, phase power factor, total power factor. Programmable data collection interval. All these daily, monthly and profile data live 60 days
@Event record: Recording the last 400 events such as cover opening, energy differences, power differences, phase sequence disorder, reverse current, TOD and tariff programming, RTC abnormality, low battery voltage, self running, decreasing of energy consumption, stop metering, abnormal communication of RS485, terminal power on or off, overload, overcurrent, over voltage, no voltage with current, no voltage and current, current imbalance, over compensation of reactive power, inadequate compensation of reactive power etc
@Immediate abnormal events information report, such as the name of manufacturer, the time of its happening and recovering, the content etc
@RTC calibration: Terminal RTC calibrated by master server, programmable interval for calibration, meter RTC calibrated by terminal
@Read last settlement of electricity consumption under power failure condition
@Data security: Terminal password for parameter editing, 24 hours parameter editing rejection for repeated wrong password input. Encryption-zipped data for communication
@Manage up to 16 multi-function meters
@Harmonics analysis: Analyzes up to 21st harmonic of voltage and current, the ratio of voltage and current distortion
@LED indication: Operational state, communication state, active/reactive energy pulse
@For details, please refer to User Manual
v id="StyleTableProd">
Accuracy Class
 
Active
 
1.0.
 
Communication interface
 
GPRS/CDMA, 9.6kbps ~115.2kbps
 
Reactive
 
2.0
 
RS485, 1.2kbps ~38.4kbps
 
Rated Voltage
 
3—220/380V
 
RS232, 1.2kbps ~115.2kbps
 
Normal Operational Voltage
 
0.8Un~1.2Un
 
IR, 1.2kbps ~9.6kbps
 
Limited Operational Voltage
 
0~1.3Un
 
Ethernet(optional), 10M/100M
 
Current Specification
 
3—1( 2)A, 3—5( 10)A
 
Operational Temperature
 
-25~55
 
Reference Frequency
 
50/60Hz
 
Limited Operational Temperature
 
-25~65
 
Power Consumption
 
‰¤3W (static)
 
‰¤5 W(max)
 
Storage Temperature
 
-25~70
 
RTC Accuracy
 
0.3s/d(23)
 
Average Rel. Humidity
 
‰¤95%
 
RTC  Battery
 
3.0VDC,Cap.‰¥1000mAh
 
Display
 
LCD
 
Data reserve
 
100 years
 
Communication Battery
 
4.8VDC,Cap.‰¥730mAh
 
Remote state
 
5 routs of state detection
 
Dimension
 
274mm—165mm—70mm
 

Wholesale Intelligent On The Spot Terminal from china suppliers

Intelligent On The Spot Terminal Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Sanxing Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0